California Energy Code Compliance and HERS testing and certification in Santa Clarita, California. CalHERS Energy provides TAB Certified professionals serving Santa Clarita and the surrounding area since 2010. Call us today to schedule your project or request a free quote.
Phone: (916) 888-8770
Santa Clarita enforces Title 24 energy compliance under Climate Zone 9 through the City of Santa Clarita Building and Safety Division at 23920 Valencia Boulevard. The third-largest city in Los Angeles County and the filming location for hundreds of TV shows and movies — home to Six Flags Magic Mountain and the College of the Canyons — Santa Clarita's HVAC commissioning demand spans film and television production facilities, theme park entertainment venues, healthcare, and one of the most active new residential construction markets in Southern California. The city falls under South Coast AQMD jurisdiction. SCE serves the area. Santa Clarita Valley's hot, dry summers and proximity to fire-prone areas create unique HVAC challenges including smoke filtration requirements for new residential construction.
City of Santa Clarita Building and Safety Division
The Santa Clarita Building and Safety Division at 23920 Valencia Boulevard, Santa Clarita, CA 91355, issues mechanical permits and enforces Title 24 energy code compliance. NRCA mechanical acceptance test certificates are required at final inspection for all commercial HVAC systems. ECC (formerly HERS) test results must be registered with an approved ECC Provider (such as CHEERS) before certificate of occupancy for residential projects. South Coast AQMD Authority to Construct permits are required concurrently for large commercial HVAC equipment above emission thresholds.
HERS (Home Energy Rating System) testing is California's verification method to ensure HVAC installations meet Title 24 energy code requirements. A HERS Rater independently tests duct leakage, refrigerant charge, airflow, and fan efficacy. This third-party verification is required for all new construction, HVAC changeouts, and additions to confirm the installed system performs as designed and complies with California's energy efficiency standards.
ECC (Energy Code Compliance) testing is the broader category that includes HERS testing for residential and small commercial projects. HERS specifically refers to the testing protocols and registry system used in California. Both terms are often used interchangeably. The key tests include duct leakage (QC/QS), refrigerant charge verification, airflow (CFM per ton), and fan watt draw—all registered in the HERS registry for building department verification.
CF3R (Certificate of Field Verification and Diagnostic Testing) is the official California Energy Commission form documenting HERS test results. When testing passes, the HERS Rater registers the CF3R in the HERS registry database, generating a unique registration number. Building inspectors verify this registration before issuing final permits. Failed tests require remediation by the contractor and retesting before registration.
HERS testing typically costs $250-$500 per system for residential projects, with multi-family and commercial projects priced based on the number of systems. On-site testing takes 1-2 hours per system. Pricing varies by location, system complexity, and accessibility. For an accurate quote specific to your project, email your permit details to Office@calherstab.com or submit through our contact form.
Common HERS failures include: duct leakage exceeding 4% (QC) or 8% (QS) limits due to poor mastic application or unsealed connections; incorrect refrigerant charge from improper installation or line set length issues; airflow below 350 CFM per ton from restrictive filters or undersized returns; and fan watt draw exceeding limits from improper motor settings. Contractors can prevent failures by following manufacturer specifications and performing their own pre-tests.
HERS testing should be scheduled after HVAC installation is complete, thermostat is installed and operational, electrical service is connected, and ductwork is accessible (before drywall covers supply boots if testing to QS standard). Allow 24-48 hours notice for scheduling. We recommend coordinating with your contractor to ensure the system has been pre-tested and any issues resolved before our arrival.
Yes, under Title 24-2022 and the 2026 Energy Code, HVAC alterations and replacements in existing buildings require HERS verification. This includes changeouts, duct modifications, and system additions. Permit requirements have expanded to include more retrofit scenarios. Building departments are increasingly enforcing these requirements, making HERS testing essential for permit final and avoiding code violations.
The 2026 Title 24 Energy Code (effective January 1, 2026) introduces stricter duct leakage limits, expanded heat pump requirements, enhanced envelope testing protocols, and updated fan efficacy standards. Projects permitted after this date must meet the new requirements. Our HERS Raters are trained on 2026 code updates and can advise on compliance strategies during your project planning phase.