- What does cleanroom testing and certification include?
- Cleanroom certification verifies that a room performs to its ISO 14644 class. Standard tests are airborne particle counts, HEPA/ULPA filter integrity (leak) testing, airflow velocity and volume, air change rate, room pressure differentials and, where required, recovery time and airflow visualization. We also test, adjust and balance the HVAC system that the cleanroom depends on.
- How is a cleanroom certified, step by step?
- 1) Confirm the target ISO class, the occupancy state (as-built, at-rest or operational) and the standard your quality system requires. 2) Test filters, airflow, pressures and particle counts. 3) Document every result with calibrated-instrument records. 4) Issue a certification report that states pass or fail for each test. Failed items are corrected and re-tested, and the report is then ready for audits.
- How often do cleanrooms need recertification?
- ISO 14644-2 sets maximum test intervals: particle counts every 6 months for ISO Class 5 or cleaner and every 12 months for Class 6 and above, with airflow and pressure checks at least every 12 months. USP <797> and <800> compounding areas must be recertified at least every 6 months and after any move, repair or major change. Your quality system, GMP or customer requirements may be stricter.
- What do the ISO cleanroom classes mean?
- ISO 14644-1 limits the number of particles of 0.5 micron and larger per cubic meter of air: ISO Class 5 allows 3,520, ISO Class 6 allows 35,200, ISO Class 7 allows 352,000 and ISO Class 8 allows 3,520,000. The lower the class number, the cleaner the room. Federal Standard 209E classes (such as Class 100) were withdrawn in 2001 but are still referred to in older documents.
- What is HEPA filter integrity (leak) testing?
- HEPA filters are rated to capture at least 99.97% of 0.3 micron particles. An integrity test challenges the filter with an aerosol (PAO) upstream and scans the filter face and seals downstream with a photometer. A penetration of about 0.01% of the upstream concentration is typically treated as a leak (IEST-RP-CC034, ISO 14644-3 methods). Leaks are repaired or the filter is replaced, then re-tested.
- Which standards do you test to?
- We test to the standard that governs your facility: ISO 14644-1, -2 and -3 for classification and testing, USP <797> and <800> for pharmacy compounding areas, and the FDA aseptic processing guidance or EU GMP Annex 1 expectations for pharmaceutical and biotech manufacturing. If your quality system specifies a protocol, we follow it.
- What ISO classes can you certify?
- We certify cleanrooms from ISO Class 5 through ISO Class 8. This includes pharmaceutical compounding rooms (USP 797/800), medical device manufacturing, laboratories and electronics assembly areas.
- What do you need to give a cleanroom testing quote?
- Send the number of rooms, floor area, target ISO class, occupancy state, number of HEPA/ULPA filters, the standard or protocol you follow and your deadline. Drawings or a previous certification report help. We reply with a written quote after reviewing the scope.
- Do you provide cleanroom testing services across California?
- Yes. We are based in Sacramento and serve Northern California, and we take larger cleanroom projects statewide. We can run particle counts, filter leak testing, airflow and pressure testing and air balancing in one visit.